The Lancer 115V Power Cord Grounded Extension USA is the heavy-duty grounded electrical connection cable responsible for delivering line voltage to the dispenser's power supply. Built with moisture-resistant insulation and a molded 3-prong plug to withstand the rigorous conditions of commercial beverage environments.

Problem Solved: Restores safe electrical delivery and eliminates machine-reset issues caused by faulty wiring or internal cord shorts. Replaces brittle, frayed, or charred power cables.

Symptoms of Failure: The unit losing power when the cord is moved, brittle or frayed insulation, or the unit resetting whenever the compressor kicks in due to insufficient current carry.

Technician’s Note: Ensure the cord is routed away from refrigeration drain pans. Continuous moisture exposure can lead to insulation rot and fire hazards. Always verify the outlet ground before commissioning the machine.
Technical Specifications:
  • Voltage: 115V
  • Type: Grounded 3-Prong (USA Spec)
  • Application: Line Power Delivery
  • Manufacturer: Lancer
$7.45

Original: $21.28

-65%
Lancer Grounded 115V Power Cord Extension - 21-0085-SP—

$21.28

$7.45

Lancer Grounded 115V Power Cord Extension - 21-0085-SP

The Lancer 115V Power Cord Grounded Extension USA is the heavy-duty grounded electrical connection cable responsible for delivering line voltage to the dispenser's power supply. Built with moisture-resistant insulation and a molded 3-prong plug to withstand the rigorous conditions of commercial beverage environments.

Problem Solved: Restores safe electrical delivery and eliminates machine-reset issues caused by faulty wiring or internal cord shorts. Replaces brittle, frayed, or charred power cables.

Symptoms of Failure: The unit losing power when the cord is moved, brittle or frayed insulation, or the unit resetting whenever the compressor kicks in due to insufficient current carry.

Technician’s Note: Ensure the cord is routed away from refrigeration drain pans. Continuous moisture exposure can lead to insulation rot and fire hazards. Always verify the outlet ground before commissioning the machine.
Technical Specifications:
  • Voltage: 115V
  • Type: Grounded 3-Prong (USA Spec)
  • Application: Line Power Delivery
  • Manufacturer: Lancer

Product Information

Shipping & Returns

Description

The Lancer 115V Power Cord Grounded Extension USA is the heavy-duty grounded electrical connection cable responsible for delivering line voltage to the dispenser's power supply. Built with moisture-resistant insulation and a molded 3-prong plug to withstand the rigorous conditions of commercial beverage environments.

Problem Solved: Restores safe electrical delivery and eliminates machine-reset issues caused by faulty wiring or internal cord shorts. Replaces brittle, frayed, or charred power cables.

Symptoms of Failure: The unit losing power when the cord is moved, brittle or frayed insulation, or the unit resetting whenever the compressor kicks in due to insufficient current carry.

Technician’s Note: Ensure the cord is routed away from refrigeration drain pans. Continuous moisture exposure can lead to insulation rot and fire hazards. Always verify the outlet ground before commissioning the machine.
Technical Specifications:
  • Voltage: 115V
  • Type: Grounded 3-Prong (USA Spec)
  • Application: Line Power Delivery
  • Manufacturer: Lancer