🎉 Up to 70% Off Selected ItemsShop Sale
Lancer Probe Assembly with Springs for Ice Bank Control - 52-1897-SP
HomeStore

Lancer Probe Assembly with Springs for Ice Bank Control - 52-1897-SP

Lancer Probe Assembly with Springs for Ice Bank Control - 52-1897-SP

The Lancer Probe Assembly with Springs is the primary liquid-level and temperature sensing component for the water bath. It sends resistance signals to the control board to manage the refrigeration cycle, ensuring the compressor builds a consistent ice bank without freezing the entire tank solid.

Problem Solved: Corrects refrigeration logic failures where the compressor runs 24/7 or fails to kick on at all. The spring-loaded design ensures the probe maintains a secure electrical ground against the tank frame, preventing 'ghost' readings that disrupt cooling.

Symptoms of Failure: An oversized ice bank that 'bridges' and blocks the agitator propeller, beverages serving warm despite power to the unit, or the refrigeration deck short-cycling.

Technician’s Note: Mineral scale buildup on the probe tips acts as an insulator. Before replacing, clean the stainless steel tips with a fine scouring pad; often, removing the lime scale restores accurate sensing logic immediately.
Technical Specifications:
  • Manufacturer: Lancer
  • Application: Ice Bank Control (IBC)
  • Design: Spring-Loaded Grounding
  • Compatibility: Lancer Remote Chillers and CED Units
$6.72

Original: $19.21

-65%
Lancer Probe Assembly with Springs for Ice Bank Control - 52-1897-SP—

$19.21

$6.72

Lancer Probe Assembly with Springs for Ice Bank Control - 52-1897-SP

The Lancer Probe Assembly with Springs is the primary liquid-level and temperature sensing component for the water bath. It sends resistance signals to the control board to manage the refrigeration cycle, ensuring the compressor builds a consistent ice bank without freezing the entire tank solid.

Problem Solved: Corrects refrigeration logic failures where the compressor runs 24/7 or fails to kick on at all. The spring-loaded design ensures the probe maintains a secure electrical ground against the tank frame, preventing 'ghost' readings that disrupt cooling.

Symptoms of Failure: An oversized ice bank that 'bridges' and blocks the agitator propeller, beverages serving warm despite power to the unit, or the refrigeration deck short-cycling.

Technician’s Note: Mineral scale buildup on the probe tips acts as an insulator. Before replacing, clean the stainless steel tips with a fine scouring pad; often, removing the lime scale restores accurate sensing logic immediately.
Technical Specifications:
  • Manufacturer: Lancer
  • Application: Ice Bank Control (IBC)
  • Design: Spring-Loaded Grounding
  • Compatibility: Lancer Remote Chillers and CED Units

Product Information

Shipping & Returns

Description

The Lancer Probe Assembly with Springs is the primary liquid-level and temperature sensing component for the water bath. It sends resistance signals to the control board to manage the refrigeration cycle, ensuring the compressor builds a consistent ice bank without freezing the entire tank solid.

Problem Solved: Corrects refrigeration logic failures where the compressor runs 24/7 or fails to kick on at all. The spring-loaded design ensures the probe maintains a secure electrical ground against the tank frame, preventing 'ghost' readings that disrupt cooling.

Symptoms of Failure: An oversized ice bank that 'bridges' and blocks the agitator propeller, beverages serving warm despite power to the unit, or the refrigeration deck short-cycling.

Technician’s Note: Mineral scale buildup on the probe tips acts as an insulator. Before replacing, clean the stainless steel tips with a fine scouring pad; often, removing the lime scale restores accurate sensing logic immediately.
Technical Specifications:
  • Manufacturer: Lancer
  • Application: Ice Bank Control (IBC)
  • Design: Spring-Loaded Grounding
  • Compatibility: Lancer Remote Chillers and CED Units