Lancer 4-Circuit Cage Assembly for 2500 Chiller - 23-0919
The Lancer Cage Assembly 4 Circuit 2500 Chiller is the internal manifold support and fluid-shaping assembly designed to house brix adjusters and solenoids. It maintains the precise spacing required for the valve plungers to seat correctly against the product coils in a 4-circuit configuration.
Problem Solved: Corrects manifold-level syrup seepage and ensures stable, leak-free seat for valve plungers in chilling systems. Replaces cages with stress-cracked ports that cause pressure loss and foaming.
Symptoms of Failure: Persistent dripping from nozzles, valves 'wobbling' in their mounting, or visible syrup buildup around the internal water bath manifold ports.
- Circuit Count: 4 Independent Circuits
- Compatibility: Lancer 2500 Chiller Series
- Application: Internal Flow Control Housing
- Manufacturer: Lancer
Original: $864.41
-65%$864.41
$302.54Lancer 4-Circuit Cage Assembly for 2500 Chiller - 23-0919
The Lancer Cage Assembly 4 Circuit 2500 Chiller is the internal manifold support and fluid-shaping assembly designed to house brix adjusters and solenoids. It maintains the precise spacing required for the valve plungers to seat correctly against the product coils in a 4-circuit configuration.
Problem Solved: Corrects manifold-level syrup seepage and ensures stable, leak-free seat for valve plungers in chilling systems. Replaces cages with stress-cracked ports that cause pressure loss and foaming.
Symptoms of Failure: Persistent dripping from nozzles, valves 'wobbling' in their mounting, or visible syrup buildup around the internal water bath manifold ports.
- Circuit Count: 4 Independent Circuits
- Compatibility: Lancer 2500 Chiller Series
- Application: Internal Flow Control Housing
- Manufacturer: Lancer
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
The Lancer Cage Assembly 4 Circuit 2500 Chiller is the internal manifold support and fluid-shaping assembly designed to house brix adjusters and solenoids. It maintains the precise spacing required for the valve plungers to seat correctly against the product coils in a 4-circuit configuration.
Problem Solved: Corrects manifold-level syrup seepage and ensures stable, leak-free seat for valve plungers in chilling systems. Replaces cages with stress-cracked ports that cause pressure loss and foaming.
Symptoms of Failure: Persistent dripping from nozzles, valves 'wobbling' in their mounting, or visible syrup buildup around the internal water bath manifold ports.
- Circuit Count: 4 Independent Circuits
- Compatibility: Lancer 2500 Chiller Series
- Application: Internal Flow Control Housing
- Manufacturer: Lancer