The Lancer 115V 24 lb 6 valves Delta 9100 Line Chiller is a high-performance remote refrigeration unit designed to maintain product temperatures for towers located far from the main supply. It utilizes a 24 lb thermal ice-bank battery in a submerged water bath to Ensure beverages reach the faucet at a consistent 40F or below.

What it Solves: Provides a self-contained cooling solution that ensures beverages remain served at 40F or below, even during peak rush surges. Perfect for long-draw draught systems where carbonation retention is critical.

Symptoms of Failure: Beverages served warm at the tower, refrigeration deck failing to build an ice bank, or findings of 'ice-bridging' in the water bath which block the agitator motor.

Technician’s Note: Maintain a minimum of 4 inches of clearance on all sides for airflow. Restricted ventilation is the primary cause of compressor overheating. Check the water bath level monthly to ensure probe conductivity and ice bank formation.Technical Specifications:
  • Voltage: 115V
  • Valve Count: 6 Circuit Compatibility
  • Cooling: 24 lb Ice Bank (CED)
  • Manufacturer: Lancer
$1,269.64

Original: $3,627.54

-65%
Lancer 115V 6-Valve Delta 9100 Line Chiller - 85-9951Z-20-GB—

$3,627.54

$1,269.64

Lancer 115V 6-Valve Delta 9100 Line Chiller - 85-9951Z-20-GB

The Lancer 115V 24 lb 6 valves Delta 9100 Line Chiller is a high-performance remote refrigeration unit designed to maintain product temperatures for towers located far from the main supply. It utilizes a 24 lb thermal ice-bank battery in a submerged water bath to Ensure beverages reach the faucet at a consistent 40F or below.

What it Solves: Provides a self-contained cooling solution that ensures beverages remain served at 40F or below, even during peak rush surges. Perfect for long-draw draught systems where carbonation retention is critical.

Symptoms of Failure: Beverages served warm at the tower, refrigeration deck failing to build an ice bank, or findings of 'ice-bridging' in the water bath which block the agitator motor.

Technician’s Note: Maintain a minimum of 4 inches of clearance on all sides for airflow. Restricted ventilation is the primary cause of compressor overheating. Check the water bath level monthly to ensure probe conductivity and ice bank formation.Technical Specifications:
  • Voltage: 115V
  • Valve Count: 6 Circuit Compatibility
  • Cooling: 24 lb Ice Bank (CED)
  • Manufacturer: Lancer

Product Information

Shipping & Returns

Description

The Lancer 115V 24 lb 6 valves Delta 9100 Line Chiller is a high-performance remote refrigeration unit designed to maintain product temperatures for towers located far from the main supply. It utilizes a 24 lb thermal ice-bank battery in a submerged water bath to Ensure beverages reach the faucet at a consistent 40F or below.

What it Solves: Provides a self-contained cooling solution that ensures beverages remain served at 40F or below, even during peak rush surges. Perfect for long-draw draught systems where carbonation retention is critical.

Symptoms of Failure: Beverages served warm at the tower, refrigeration deck failing to build an ice bank, or findings of 'ice-bridging' in the water bath which block the agitator motor.

Technician’s Note: Maintain a minimum of 4 inches of clearance on all sides for airflow. Restricted ventilation is the primary cause of compressor overheating. Check the water bath level monthly to ensure probe conductivity and ice bank formation.Technical Specifications:
  • Voltage: 115V
  • Valve Count: 6 Circuit Compatibility
  • Cooling: 24 lb Ice Bank (CED)
  • Manufacturer: Lancer